Seen on: 600 Series, later control
EC 06: Refrigerator Evaporator Sensor Fault
EC 06 means the sensor on the refrigerator evaporator of a later 600 Series read open, shorted or erratically. The fresh-food compartment can look entirely normal while SERVICE flashes by itself. Sub-Zero Repair Redmond checks the sensor, its connections and its wiring back to the control; call (425) 905-2822.
| Means | The refrigerator evaporator thermistor read open or shorted for ten seconds or more, or repeatedly gave erratic temperatures. |
|---|---|
| Check first |
|
| Needs a technician |
|
Two sensors on the fresh-food side
The refrigerator side of a later 600 Series carries two sensors. One reads the compartment air; the other reads the evaporator, the coil that does the cooling. EC 05 belongs to the first and EC 06 to the second.
A loose plug looks like a dead part
Sub-Zero’s manual words the fault as disconnected, shorted or misread. A connector that has worked loose reads the same as a failed sensor, so the wiring is checked before a part is changed.
Older units
A 600 Series built before serial number 1810000 shows the same pattern, normal temperatures with SERVICE flashing, for the same sensor. That earlier control stores no codes, so the diagnosis rests on the display and a meter.
Asked on the phone
- Why is SERVICE flashing when the temperatures look fine?
- The display shows the compartment sensors, not the coil. When the sensor on the refrigerator evaporator fails, readings can stay normal while the control flags the fault. Sub-Zero's manual lists that exact pattern under this sensor. Sub-Zero Repair Redmond, (425) 905-2822, confirms it in Diagnostic Mode.
EC 06 on your display?
Sub-Zero Repair Redmond · $89 service call, deducted once the repair goes ahead · on site 0800 to 2000 hrs, all seven days
- Checked by
- Dean Halvorsen
- Bench
- sealed systems and airflow
- Trade
- 19 yrs
- Card
- EPA 608 certified
- Revised