Seen on: 600 Series, early control · 600 Series, later control
The Flashing SERVICE Indicator
A flashing SERVICE light on a Sub-Zero 600 Series means the control saw a temperature or ice maker problem, or the condenser needs cleaning. Look at the condenser first. If it is clean and the light keeps flashing, call Sub-Zero Repair Redmond on (425) 905-2822 and read us the rest of the display.
| Means | The control has flagged a temperature or ice maker problem, or a condenser that needs cleaning. What it pairs with narrows it down. |
|---|---|
| Check first |
|
| Needs a technician |
|
What it pairs with
SERVICE rarely flashes alone for long. The rest of the display usually says where to look:
- ICE and SERVICE together. The control held the ice maker’s water valve open for more than fifteen seconds. A jammed cube, an ice maker out of level or low water pressure are the usual reasons.
- EE in place of a temperature. The sensor for that compartment has gone open or shorted, or its wiring has.
- A warm compartment. A real temperature problem: airflow, a fan, the defrost circuit or the sealed system.
- Normal temperatures, SERVICE alone. Sub-Zero’s manuals point at the refrigerator evaporator sensor.
Early and later controls
On a 600 Series built before serial number 1810000 the condenser warning reads VACUUM CONDENSER instead, and no codes are stored. On the later control a technician can pull stored codes from the keys, which is why the model and serial off the tag matter before the visit.
Clearing it
Once the fault is repaired, a flashing SERVICE light clears when the unit is switched off and on again at the control panel.
Asked on the phone
- The light is on but not flashing. Is that different?
- Yes. On the later 600 Series a steady SERVICE light after Diagnostic Mode means codes are stored in memory. They are cleared once the fault is repaired, by holding the bell key for fifteen seconds. Sub-Zero Repair Redmond, (425) 905-2822, reads them before clearing anything.